14:09 Condensate Pumps, Electronic Switchs, Accessories

Condensate pumps

Condensate pumps and electronic switches

SAHARA

SAHARA

The SAHARA is an electronic condensate removal system that fits neatly inside even the smallest high wall split air conditioner.

At the heart of the pump is its solid state electronic control system that works with a special timer.

Technical Data:
Power: 30 W when running
Relay switching: 250 VAC, 5 A, 1250 VA
Pump capacity: 14 l/h
Discharge head: 5 m , 30 m
Ambient temperature: 0 °C to 50 °C
Thermal protection: cut-out 80 °C
reset 35 °C to 65 °C
Sensor-pump tube: length 1.5m, Ø 3.18 mm


Part No 4678482

Download:
> Instruction manual


KAROO

KAROO

The KAROO is a Drain Pan Pump which turns on to remove the defrost water from a refrigeration cabinet, or condensate water from an air conditioner. The water level is measured by a sensitive electronic sensor and this controls the operation of the pump via the fully-encapsulated circuitry.

Technical Data:
Power: 30 W pump running,
0.33 W pump off
Discharge head: 6 m , 30 m
Water temperature: 40 °C max.
Thermal protection: cut-out 50 °C
Discharge tube size: 6 – 6.35 mm (1/4" i.d.)
Part No 4678512

Download:
> Instruction manual

YUMA

YUMA

The YUMA fills the continuing need for a small pump which will fit inside the tubing chase of a high-wall-mount air conditioner, and will quietly and efficiently pump all the condensate to a drain. Completely automatic operation is enhanced by the Electronic Noise Control© circuitry to give quiet starting and stopping, as well as power control to regulate the amount of power needed to remove the condensate.

Technical Data:
Power: 30 W when running
Alarm relay rating: 250 V,

5 A max. break on fault
Pumping capacity: 12 l/h
Discharge: 15 m , 100 m ft
Water temperature: 25 °C max.
Ambient temperature: 0 °C to + 50 °C
Discharge tube size: 6 mm i.d.
Part No 4678520

Download:
> Instruction manual

GOBI

GOBI

The GOBI is a condensate discharge module designed for modern wall mounted air conditioners. Because of the aesthetic design the GOBI can be used with all wall mounted air conditioners; it needs no space inside the air conditioner!

Technical Data:
Power: 30 W
Alarm relay: 250 VAC, 5 A
Pumping capacity: 12 l/h
Ambient temperature: 0 °C to + 40 °C
Discharge head: 15 m , 60 m
Part No 4678538

Download:
> Instruction manual > Installation video

Electronic switches

LAC-EXTREME

LAC EXTREME

The LAC EXTREME is a Low Ambient Controller for all air cooled condensing units in air conditioning and refrigeration units with fan motor.

The intelligent logic programmed into these high specification controllers decides the correct speed for the outdoor fan, whether the fan should stop and for how long, to provide the maximum system efficiency.

Technical Data:
Fan motor running current: 4 A max.
Ambient temperature: -30 °C to +50 °C
Set point condensing temperature range: +30 °C to +60 °C
Input voltage from reversing valve: 24 - 240 V, 60 Hz

Part No 4678563

Download:
> Instruction manual


LAC UNIVERSAL

The LAC Universal is an electronic controller for outdoor fans on heat pumps and cooling-only air conditioners. By controlling the speed of the fan in changing ambient temperatures this electronic controller brings benefits to all air conditioning installations.
Technical Data:
Max continuous fan motor current: 2 A
Max. fan motor start current: 5 A
Controller max ambient temperature: 50 °C
Condensing temperature control range: 30 °C to 60 °C
Fan minimum speed adjustment range: 0–100%
Heat pump solenoid valve voltage: 24–250 V AC

Part No 4678555

Download:
> Instruction manual


AQUASWITCH

AQUASWITCH

The AQUASWITCH is an electronic water switch for valves, pumps and alarms. The AQUASWITCH is a small controller with a sensitive electronic circuit encapsulated inside. Constructed for all applications where a reliable switch is needed to control or indicate the presence of water.

Technical Data:
Voltage: 95 – 254 V, 50 Hz
24 V AC/DC
Max. switched relay current: 5 A
Relay switch-off delay: 2.5 +/- 0.5 seconds
Ambient temperaturerange: 0 °C to 75 °C
Water level for switching relay: 0 +/- 1/5"
(depends on water quality)

AQUASWITCH

95-254 V, 50 Hz
Part No 4678741

AQUASWITCH-24

24 V AC/DC
Part No 4678546


Download:
> Instruction manual


INVERTER_CHECK_KIT

INVERTER_CHECK_KIT_inkl_alle_Kabel

INVERTER CHECK KIT

The inverter check kit is an invaluable test kit for the analysis of problems solving with inverted-fed air conditioners.

Designed to be used both in installation and maintenance, this kit can indicate correctly-operating inverter power stages, as well as the serial-link communication between the condensing unit and the indoor units. This allows the air conditioning engineer to easily identify faults and reduces the time required for analysis and repair.

The kit contains the electronic module with a set of leads for testing the serial communications links, as well as a selection of cables and connectors for the power output terminals of the inverter.

Part No 4678571

Download: > Instruction manual


Accessories

ACOUSTIC-JACKET

ACOUSTIC JACKET

The ACOUSTIC JACKET is an accessory for the application of Sahara pumps in extreme noise sensitive environments.

The Sahara pump is inserted into the rubber sleeve and the ends are then plugged with the inserts supplied.

Part No 4678589

Download: > Instruction manual


IN-LINE_FILTER

IN-LINE FILTER

The IN-LINE FILTER fits in the drain line from an air conditioner to its condensate pump, and should be used wherever dirt particles, construction debris, hairs or greasy deposits can be washed from the drain tray down into the pump.

Part No 4678597

Download: > Instruction manual

14:08 Solenoid Valves, Access Valves

Solenoid Valves
Access Valves

...............................................................................................................................

Solenoid Valves

These valves are quality and reliability
with a lifetime up to 3,5 millions switching cycles

ERF2-230

Suitable for fluorated gas and liquid refrigerants
Max. operating pressure 35 bar
Max. refrigerant temperature -40 °C up to +125 °C

.............................................................................................................

ERS3-230

.............................................................................................................

Copper Capillary Tubes

TC-Capillary Tubes

Pure soft copper tube in coils of about 100 feet (30 m). Sealed and dehydrated small diameter plug-drawn copper capillary tubing, available in 100 foot exact length coils

.............................................................................................................

Capillary Tube Gauge

10971

Cap Gauge Tool

.............................................................................................................

Copper Capillary Tubes

TCK-Capillary Tubes

With O-ring-gasket Silver Brazing
Capillary tube with Schrader-valve opener

.............................................................................................................

Polyamid Capillary Tubes

P-2001

Polyamid capillary confectioning set
Capillary connection lines can be made easy
and directly when servicing a refrigeration unit

.............................................................................................................

Access Valves 1/4" SAE

A-31004/10

Extended copper tube style Ø 1/4"

A-31004-M-1/4"/10

With swaged tube suitable for 6 mm and 1/4" tube

A-31004-M/10

With swaged tube suitable for 6 mm Ø

.............................................................................................................

"Super-Tap" Piercing Valves for Domestic Appliance

LT-Piercing Valves

Suitable to be fitted permanently on to sealed units.
This type of piercing valve is absolutely tight
and very easy to install.
Benefits:
- Body manufactured from forged brass
- Valve spindle made from quality steel, hardened

.............................................................................................................